RAID Usable Capacity Calculator (RAID 0, 1, 5, 6, 10)
Choose a RAID level, the number of disks and the size of each disk. See the usable space in decimal terabytes (as on the disk label) and binary tebibytes (as many operating systems show it), and how much goes to redundancy.
Usable-capacity arithmetic only: it makes no claim about reliability, how many disk failures an array survives or how long a rebuild takes. All disks are taken as the same size, and the file system takes some more space.
- Usable capacity (TB)
- –
- Usable capacity (TiB)
- –
- Share of raw space usable
- –
- Raw capacity (all disks)
- –
- Space used for redundancy
- –
- Disks' worth of data space
- –
Assumptions
- All disks are the same size.
- RAID 5 keeps one disk's worth of parity and RAID 6 two; RAID 1 and RAID 10 keep two copies of everything.
- Usable capacity is before the file system, hot spares and any space set aside by the controller.
Checked 3 November 2026 Patterson, Gibson & Katz, A Case for Redundant Arrays of Inexpensive Disks (RAID), UC Berkeley UCB/CSD-87-391 (its 91% and 96% capacity figures are tests here) All sources
How it is calculated
- RAID 0: usable = N × size
- RAID 1 (2 disks) and RAID 10 (even N ≥ 4): usable = N × size ÷ 2
- RAID 5: usable = (N − 1) × size; RAID 6: usable = (N − 2) × size
- TB = 10¹² bytes; TiB = 2⁴⁰ bytes, so TiB = TB × 10¹² ÷ 2⁴⁰ ≈ TB × 0.9095
Worked example
Four 4 TB disks in RAID 5.
| You enter | |
|---|---|
| RAID level | RAID 5 (one disk of parity) |
| Number of disks | 4 |
| Size of each disk | 4 |
| Disk size unit | Terabytes (TB, 10¹² bytes) |
| You get | |
| Usable capacity (TB) | 12 TB |
| Usable capacity (TiB) | 10.914 TiB |
| Share of raw space usable | 75.00% |
| Raw capacity (all disks) | 16 TB |
| Space used for redundancy | 4 TB |
| Disks' worth of data space | 3 |
RAID 5 with 4 disks keeps 3 disks' worth of data: 12 TB, which an operating system that counts in powers of 2 shows as 10.914 TiB.
Questions
Why does my array show less than the TB figure?
Disk makers count 1 TB as 10¹² bytes (NIST: tera = 10¹²). Some software divides by 2⁴⁰ and still labels the result TB, though it is TiB (NIST binary prefixes). That is why 4 TB shows as about 3.64.
Why is RAID 1 limited to 2 disks here?
Level 1 keeps two copies of everything, so half the raw space holds data (Chen et al., Table 3). Several mirrored pairs striped together are RAID 10, which you can choose for 4 or more disks.
Sources and checks
- Patterson, Gibson & Katz, A Case for Redundant Arrays of Inexpensive Disks (RAID), UC Berkeley UCB/CSD-87-391 (its 91% and 96% capacity figures are tests here)
- Chen, Lee, Gibson, Katz & Patterson, RAID: High-Performance, Reliable Secondary Storage, UC Berkeley UCB/CSD-93-778, Table 3 (storage efficiency of RAID 0, 1, 5 and 6)
- Arpaci-Dusseau, Operating Systems: Three Easy Pieces, ch. 38 RAID (University of Wisconsin–Madison): capacity of striping, mirroring and RAID-10
Last checked: 3 November 2026. This tool passes 11 automatic tests before every release. How we check our tools
Cite this page
RAID Usable Capacity Calculator (RAID 0, 1, 5, 6, 10). GlanceDesk Compute. Last checked 3 November 2026. https://glancedeskcompute.com/
Your numbers stay on your device unless you share them.
For planning and learning. Usable-capacity arithmetic only: it says nothing about how reliable an array is or how long a rebuild takes. Check your controller or software RAID documentation. Results are estimates for planning and learning. They are not a design check and do not replace a qualified engineer or your local building/electrical code.