Mixer Mass Balance Calculator (Outlet Flow and Mass Fraction)

Mass flow in any one unit (kg/h, t/h, lb/min…). Use the same unit for every stream.

The numbers filled in are examples. Type your own.

%
%
0 for a stream with none of the component, such as pure water.
Leave 0 if only two streams mix.
%

Enter the mass flow of two or three inlet streams and the mass fraction of one component in each. See the outlet flow and its mass fraction from the steady-state total and component mass balances, in any one flow unit.

Component in the outlet (mass fraction)
–
Outlet flow (same unit as the inlets)
–
Component in the outlet (flow, same unit)
–
Everything else in the outlet (flow, same unit)
–

Assumptions

  • Steady state: nothing builds up in the mixer, so what goes in comes out.
  • No reaction: the component is neither made nor used up in the mixer.
  • One outlet stream, and all flows are mass flows in the same unit.

Checked 3 November 2026 MIT 10.213 lecture notes, Mass Balances (steady state, no reaction: rate of input = rate of output) All sources

How it is calculated

  • Total balance: outlet flow F = F1 + F2 + F3
  • Component balance: F × x = F1 × x1 + F2 × x2 + F3 × x3
  • Outlet mass fraction x = (F1x1 + F2x2 + F3x3) ÷ F

Worked example

The KFUPM ChE 201 mixing example: 924 lbm/min of 20% caustic soda solution diluted with 1,386 lbm/min of water.

You enter
Inlet 1 flow924
Component in inlet 1 (mass %)20 %
Inlet 2 flow1,386
Component in inlet 2 (mass %)0 %
Inlet 3 flow (optional)0
Component in inlet 3 (mass %)0 %
You get
Component in the outlet (mass fraction)8.000%
Outlet flow (same unit as the inlets)2,310
Component in the outlet (flow, same unit)184.8
Everything else in the outlet (flow, same unit)2,125.2

In = out at steady state: the outlet carries 2,310 in total, of which 184.8 is the component, so the outlet is 8% of it by mass.

Questions

Can I use volume flows?

Only if every stream has the same density. Mass is conserved; volume is not always (water and alcohol shrink when mixed), so convert volume flows to mass flows first.

How do I find a feed for a target outlet?

Change the flows until the outlet fraction matches the target. For two streams, F1 ÷ F2 = (x2 − x) ÷ (x − x1).

Sources and checks

Last checked: 3 November 2026. This tool passes 7 automatic tests before every release. How we check our tools

Cite this page

Mixer Mass Balance Calculator (Outlet Flow and Mass Fraction). GlanceDesk Compute. Last checked 3 November 2026. https://glancedeskcompute.com/mixer-mass-balance-calculator/

Found a wrong number? Tell us

Your numbers stay on your device unless you share them.

For learning and process planning. It is not a design check: real mixers need proper mixing, and densities change volumes. Results are estimates for planning and learning. They are not a design check and do not replace a qualified engineer or your local building/electrical code.

Related tools

Missing something? Suggest a tool