NewNew: GlanceDesk Compute, checked engineering calculators for civil, electrical and HVAC work. See what comes next.
GlanceDeskCompute

Ask an engineering tool

Try:

Answers come from the same tested tools. Nothing you type leaves your device.

Rooftop Rainwater Harvesting Calculator

The numbers filled in are examples. Type your own.

m²
The roof as seen from above: length × width from eave to eave, with overhangs. A steeper roof does not catch more. Count only the parts whose gutters lead to the tank.
mm
From your national weather service, in mm or inches. For a safer answer use a dry year's total, not the average.
Fills the runoff coefficient from New Mexico Office of the State Engineer Table 7-1 (estimates). You can still change it.
The share of the rain that reaches the tank, from 0 to 1. Tar and gravel: 0.80 to 0.85 (same table). The Texas manual says most installers allow 0.75 to 0.90 for losses such as first flush, splash and overflow.
L
Litres or US gallons. Daily use × 30 is close enough. Blank or 0 means no use: you see only what the roof collects.

Enter your roof area, the rainfall and the roof surface. See how much rainwater the roof can collect in a year, in litres or gallons, how many months of use that covers, and, with monthly rainfall, whether a tank size runs short or overflows.

Water you can collect in a year
–
In litres
–
In cubic metres
–
In US gallons
–
Months of your use this covers
–
Starting tank size where rain falls all year (one-third rule, New Mexico)
–

Assumptions

  • Water collected = roof area × rainfall × runoff coefficient; 1 mm of rain on 1 m² is 1 litre.
  • The area is the roof footprint seen from above; a steeper pitch does not catch more rain.
  • Runoff coefficients are estimates (NM OSE Table 7-1); a very light shower may give no runoff at all.
  • The tank check runs month by month from 1 January, with the same use every month (Texas manual, Chapter 4).
  • Water above the tank size overflows and is lost; a month that would end below 0 is short, and the tank is then empty.
  • The one-third rule is a starting point where rain falls through the year; with a long dry season, check month by month.

Estimate Checked 5 November 2026 Texas Water Development Board, The Texas Manual on Rainwater Harvesting, 3rd ed. (2005), Chapter 4: 0.62 gallons per ft² per inch of rain, 75–90% efficiency, roof footprint, Dallas monthly water balance (Tables 4-2 and 4-3) All sources

How it is calculated

  • Water collected (litres) = roof area (m²) × rainfall (mm) × runoff coefficient, because 1 mm on 1 m² is 1 litre
  • Imperial: 1 inch on 1 ft² is 2.3597 L = 0.6234 US gallons (the Texas and New Mexico manuals round it to 0.62)
  • Monthly rainfall: the year's water is the sum of the 12 months
  • Tank at month end = tank at the start + water collected − use; above the tank size the rest overflows; below 0 the month is short and the tank is empty
  • Months of use covered = water collected in a year ÷ use per month
  • Starting tank size where rain falls all year (one-third rule, New Mexico, yearly mode only) = water collected in a year ÷ 3

Worked example

Government of Meghalaya design example: a 50 m² roof and 280 mm of rain in the driest year of ten give 11.2 m³. Use is 5 people × 10 L a day × 30 days. Meghalaya sizes the tank for the full 11.2 m³ (3.2 m across, 1.4 m of water), not one third: with a monsoon or a long dry season, use the monthly tank check.

You enter
Rainfall you haveOne total for the year
UnitsMetric: m², mm and litres
Roof catchment area50 m²
Rainfall in a year280 mm
Roof surfaceOther: type the coefficient below
Runoff coefficient0.8
Water use per month (optional)1,500 L
You get
Water you can collect in a year11,200 L (11.2 m³)
In litres11,200 L
In cubic metres11.2 m³
In US gallons2,959 gal (US)
Months of your use this covers7.5 months

In a year with this rainfall, the roof can collect about 11,200 litres (11.2 m³). That is about 7.5 months of your use, if the tank can hold it until you need it. The one-third rule suits places where rain falls all year. With a monsoon or a long dry season, choose monthly rainfall and check a tank month by month.

Questions

Which rainfall figure should I use?

Your national weather service publishes yearly and monthly totals. An average year is not a typical one: the New Mexico manual notes that a normal year there brings about 20% less than the average, and the Meghalaya example designs for the driest year in ten. The Texas manual calls monthly median rainfall the more conservative choice.

Why do the manuals say 0.62 gallons and this tool 0.6234?

One inch of rain on one square foot is 144 cubic inches, which is 0.6234 US gallons. Both manuals round it to 0.62, so their answers are about 0.5% lower. In metric no rounding is needed: 1 mm on 1 m² is exactly 1 litre.

What tank size makes sense?

Enter monthly rainfall, your monthly use and a tank size, and read the table: if a month is short, try a bigger tank, a larger roof area or less use. Overflow means the tank fills up; a bigger tank only helps if the water is used before the next dry month. The one-third rule from New Mexico is only a starting point.

Sources and checks

Last checked: 5 November 2026. This tool passes 18 automatic tests before every release. How we check our tools

Cite this page

Rooftop Rainwater Harvesting Calculator. GlanceDesk Compute. Last checked 5 November 2026. https://glancedeskcompute.com/rainwater-harvesting-calculator/

Found a wrong number? Tell us

Your numbers stay on your device unless you share them.

This is an estimate for planning and learning: rain changes from year to year and the runoff coefficient is an estimate. For drinking water, treat and test it as your local health authority advises, and ask a qualified person about a tank on a roof or a raised stand. Results are estimates for planning and learning. They are not a design check and do not replace a qualified engineer or your local building/electrical code.

Related tools

Missing something? Suggest a tool