NewNew: GlanceDesk Compute, checked engineering calculators for civil, electrical and HVAC work. See what comes next.
GlanceDeskCompute

Ask an engineering tool

Try:

Answers come from the same tested tools. Nothing you type leaves your device.

Solar PV System Sizing Calculator (Panels, Battery, Inverter)

kWh
From your bill: monthly units (kWh) ÷ 30. Or add up watts × hours of use ÷ 1,000 for each appliance.

The numbers filled in are examples. Type your own.

h
Daily sun energy on the panels, in kWh/m² a day. Look up your place on PVGIS (EU JRC): its H(i)_d value is this number. Use a low month if you need power all year.
%
The share of the panels' rated output you really get after heat, dust, wiring and inverter losses. NREL and Sandia: usually 60–90% for new systems. PVGIS's own 1 kWp example works out at 78%.
W
The watts on the panel label (at STC). 550 W is only an example.
days
Enter 0 for a system without batteries (grid-tied). 1 covers one full day of your use.
%
The discharge cutoff from your battery's data sheet. PVGIS's off-grid example uses 40%, which leaves 60% usable.
V
For example 12, 24 or 48 V, as your inverter needs.
%
From the inverter's data sheet. The 85% example is from Sandia report SAND2001-0674.
W
Add the watts of everything that may run together. Pumps and air-conditioner motors draw several times more for a moment when they start.

Enter how much electricity you use in a day, the peak sun hours where you live and your largest load. See how many kilowatts of solar panels you need, how many panels, the battery bank for the days of backup you want, and the smallest inverter.

A first sizing for planning. Peak sun hours and losses vary by site, season and shading; check your location on PVGIS and ask a qualified installer before you buy.

Solar panels needed
–
Number of panels of your rating
–
Expected daily output from those panels
–
Battery bank (rated energy)
–
Battery bank capacity at your voltage
–
Inverter continuous rating, at least
–

Assumptions

  • Panels are sized for your daily use on an average day of the peak sun hours you enter; cloudy days and winter give less.
  • The battery covers your full daily use for the days you enter, through the inverter, without going below the cutoff.
  • The inverter must carry the largest load running at once; motor starting surges and future loads need extra.
  • Shading, panel tilt and direction are inside the peak sun hours and performance ratio you enter.

Estimate Checked 4 November 2026 Sandia National Laboratories, PV Performance Modeling Collaborative: Performance Ratio (PR = Yf ÷ Yr; Yr in hours) All sources

How it is calculated

  • Solar panels (kWp) = daily use (kWh) ÷ (peak sun hours × performance ratio) (Sandia PVPMC: PR = Yf ÷ Yr)
  • Number of panels = panels in watts ÷ one panel's watts, rounded up; expected output = panels × watts × sun hours × PR
  • Battery bank (kWh) = daily use × days of backup ÷ (inverter efficiency × (1 − discharge cutoff))
  • Battery capacity (Ah) = battery kWh × 1,000 ÷ bank voltage; inverter (kW) ≥ largest load running at once

Worked example

A home using 10 kWh a day, at 5 peak sun hours, with one day of battery backup at 48 V.

You enter
Electricity you use per day10 kWh
Peak sun hours per day (estimate)5 h
Performance ratio (after losses, estimate)78 %
Rating of one panel550 W
Days the battery must cover with no sun1 days
Lowest charge the battery may reach40 %
Battery bank voltage48 V
Inverter efficiency85 %
Largest load running at the same time3,000 W
You get
Solar panels needed2.56 kWp
Number of panels of your rating5
Expected daily output from those panels10.73 kWh/day
Battery bank (rated energy)19.61 kWh
Battery bank capacity at your voltage408 Ah
Inverter continuous rating, at least3 kW

To make 10 kWh a day with 5 peak sun hours, you need about 2.56 kWp of panels: 5 panels of 550 W. For 1 day with no sun, the battery bank needs about 19.6 kWh (408 Ah at 48 V). Choose an inverter of at least 3 kW, with room for motor starting surges.

Questions

Where do I find my peak sun hours?

On PVGIS, the European Commission's free solar tool: choose your location, and the grid-connected PV result shows H(i)_d, the daily sun energy on your panels in kWh/m². That number is your peak sun hours. For power all year, use a month with low sun.

Why is the battery bigger than my daily use?

Only part of a battery can be used (above its discharge cutoff), and the inverter loses some energy. With a 40% cutoff and an 85% inverter, 10 kWh of use needs about 19.6 kWh of rated battery for one day.

Sources and checks

Last checked: 4 November 2026. This tool passes 8 automatic tests before every release. How we check our tools

Cite this page

Solar PV System Sizing Calculator (Panels, Battery, Inverter). GlanceDesk Compute. Last checked 4 November 2026. https://glancedeskcompute.com/solar-pv-system-sizing-calculator/

Found a wrong number? Tell us

Your numbers stay on your device unless you share them.

A first sizing for planning and comparing quotes, not a design. Roof space, shading, wiring, protection and local connection rules need a qualified installer. Results are estimates for planning and learning. They are not a design check and do not replace a qualified engineer or your local building/electrical code.

Related tools

Missing something? Suggest a tool